Diatrom 400

6 951,45€
Description

Twin operative activity: two output channels for monopolar cutting / two independent setting and output channels for the most frequent monopolar coagulation. Spray coagulation available by hand switch or foot switch. Wide bipolar features: bipolar cutting current with selectable bleeding control / slow blend cutting current. Separately activable automatic start and automatic stop coagulation. Surgeon and patient total safety: acceptability of contact impedance between patient body and return electrode continuously watched by skinplate electronic control (SPEC). Excessive power delivery time warned. H.F. leakage currents continuously monitored. Mains voltage variations automatically compensated before to start the delivery of H.F. power extention driver and interlock signals: drived output connection to external argon plasma unitand smoke evacuator unit automatic self diagnosis. Automatic diagnostic control of the actual complete functionality of the electronic unit and the connected accessories and coded report of found failures speedy coagulation also said fulgurate or forced coagulation.

Standard accessories

Power supply cord 5m
Disposable handle with switches
Reusable handpiece with finger switches
Short blade electrode
Long blade electrode
Ball electrode
Cable for disp. plate
Splitted disposable plates
Electrode cleaning sponge
Double water-proof foot-switch

Characteristics            

Frequency  425 kHz - 525 kHz.                                                                                       
Max output monopolar pure                            
CUT                 300 W - 300 0hm / 400 W - 300 0hm.
CUT 80%         250 W - 300 0hm / 300W - 300 0hm.
Max output power monopolar cut-coag        
CUT 60%        200 W - 300 0hm / 250 W - 300 0hm.
CUT 40%         150 W - 300 0hm / 200W - 300 0hm.
Maximum output power monopolar cut        
ENHANCED     200 W - 500 0hm / 250 W - 500 0hm.
Max output power monopolar cut-coag        
BLEND             200 W - 300 0hm / 250 W - 300 0hm.
SPEEDY            100 W - 500 0hm / 120 W - 500 0hm.
DEEP                100 W - 200 0hm / 120 W - 200 0hm.
Max output power monopolar coag              
SPRAY               70 W - 200 0hm / 100 W - 200 0hm.
SPRAY ARGON70 W - 200 0hm / 100 W - 200 0hm.
Max output monopolar cut-coag                    
CUT                   95 W - 200 0hm / 100 W - 200 0hm.
CUT 80%          95 W - 200 0hm / 100 W - 200 0hm.
CUT 60%          95 W - 200 0hm / 100 W - 200 0hm.
Maximum output power bipolar cut coag      
CUT 40%          60 W - 150 0hm / 90 W - 150 0hm.
BLEND              90 W - 150 0hm / 90 W - 150 0hm.
Maximum output power bipolar cut-coag     
COAG               70 W - 100 0hm / 70 W - 100 0hm.

Electrode neutre F. 
Power supply 115-230Vca / 50-60Hz.
Power max absorption 300 VA / 350 VA
Dimensions 370 x 320 x 144 mm (h).
Weight 6 kg.
Conform to the directive 93/42/CEE II b.
Safety class I CF.

Application 
Ambulatory surgery / general surgery / pediatric surgery / Otorhinolaryngology / gynecology / plastic surgery / thoracic surgery / dermatology / vascular surgery / emergencies / veterinary / endoscopy / gastroenterology / pneumology / urology / neurosurgery / orthopedics.